NEC XN120 - Serial connection

These instructions help you configure your NEC XN120 phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

Support files

Ensure the following support files exist in the /config/ folder of the TIM Plus application:

NEC DXE.TDT
NEC DXE.TDS

Contents

Configure the SMDR output

info

You may need to purchase a license to enable SMDR on this PBX. Please speak to your system maintainer if you are unsure.

Follow the steps below to configure the SMDR output on your NEC XN120:

  1. Log in to your PC Pro/Web Pro software.

  2. To configure SMDR output by serial port, apply the following settings:

AdapterProgramming codeValueDescription
NTCPU - Serial10-21-021NTCPU Hardware Setup - Baud Rate for Com Port. Choose from the three available options: 0(4800), 1(9600) and 2(38400).
35-01-011SMDR Options - Output Port Type.
  1. Apply the following settings in the programming sections below:
Programming codeValueDescription
14-01-061Basic Trunk Data Setup - SMDR Print.
15-01-031Basic Extension Data Setup - SMDR Print.
35-01-030SMDR Options - Header Language.
35-01-040SMDR Options - Omit (Mask) Digits.
35-01-050SMDR Options - Minimum Number of SMDR Digits.
35-01-060SMDR Options - Minimum Call Duration.
35-01-070SMDR Options - Minimum Ringing Time.
35-01-08DefaultSMDR Options - SMDR Format.
35-02-010SMDR Output Options - Toll Restricted Call.
35-02-021SMDR Output Options - PBX Calls.
35-02-031SMDR Output Options - Display Trunk Name or Numbers.
35-02-040SMDR Output Options - Daily Summary.
35-02-050SMDR Output Options - Weekly Summary.
35-02-060SMDR Output Options - Monthly Summary.
35-02-081SMDR Output Options - Incoming calls.
35-02-090SMDR Output Options - Print Name or Numbers.
35-02-100SMDR Output Options - All Lines Busy (ALB) Output.
35-02-120SMDR Output Options - DID Table Name Output.
35-02-131SMDR Output Options - CLI Output when DID to Trunk.
35-02-141SMDR Output Options - Date.
35-02-151SMDR Output Options - CLI/DID Number Switching.
35-02-161SMDR Output Options - Print Trunk Name or Received Dialled Number.
35-02-170SMDR Output Options - Print Account Code or Caller ID Name.
35-02-18DefaultSMDR Output Options - Caller ID Name Output Method.
80-05-011Date Format for SMDR and System Reports.

Installing NetPBX

To capture SMDR data from your NEC XN120 using a serial connection, you first need to install the NetPBX software to collect the data from the serial port and send it to TIM Plus. For setup instructions, click on the link below:

Install and configure NetPBX

Configure TIM Plus

Follow the steps below to configure TIM Plus to connect to your NEC XN120:

  1. Click on the Directory tab.
  2. If you don't have a site set up, press Add and select PBX from the drop-down menu. In the dialogue window, name your site and then select Add.
  3. Locate the site object you want to configure in the Directory, click on it and select Properties. TIM Plus PBX Connection Properties
  4. In the Site Properties window, select NEC DXE from the PBX model drop-down list.
  5. In the Connection method field, select No connection required from the drop-down list.
  6. Click on the Options tab and tick the Keep a local backup of any data tickbox, as shown below TIM Plus PBX backup options
  7. Click on the Save button to apply the settings.