Panasonic KX-TDA/E/NCP500-1000/NS Range - IP connection
These instructions help you configure your Panasonic KX-TDA/E/NCP500/1000/NS Range phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.
Support files
Ensure the following support files exist in the /config/
folder of the TIM Plus application:
Panasonic KX-TD Series.TDS
Panasonic KX-TD Series.TDT
Contents
Configure the SMDR output
info
You may need to purchase a license to enable SMDR on this PBX. Please speak to your system maintainer if you are unsure.
Follow the instructions below to configure your Panasonic to output SMDR data to TIM Plus via an IP connection:
- Log in to the Panasonic Maintenance Console program.
- Click on the 11. Maintenance tab from the left-hand menu.
- Click on the SMDR tab and configure the options as shown below:
- Click on the SMDR Options tab and configure the options as shown below:
- Click on the Apply button to save the changes.
Configure TIM Plus
Follow the steps below to configure TIM Plus to connect to your Panasonic KX-TDA/E/NCP500/1000/NS Range:
- Click on the
Directory
tab. - If you don't have a site set up, press
Add
and selectPBX
from the drop-down menu. In the dialogue window, name your site and then selectAdd
. - Locate the site object you want to configure in the Directory, click on it and select
Properties
. - In the Site Properties window, select Panasonic KX-TD Series from the PBX model drop-down list.
- In the Connection method field, select Actively connect to PBX from the drop-down list.
- In the Host field, enter the IP address of your phone system.
- In the Port field, enter 2300.
- Leave the Username field blank. In the Password field, enter the password required to connect to your phone system, by default PCCSMDR.
- In the Connection script field, select Panasonic from the drop-down list.
- Click on the
Options
tab and tick the Keep a local backup of any data tickbox, as shown below - Click on the
Save
button to apply the settings.